ALTAIR V5 DN15/20

VOLUMETRIC METER

Application

ALTAIR V5 represents the latest generation of volumetric meters developed within the framework of the MID and European standards to meet field requirements. ALTAIR V5 is a particularly compact and robust meter, adapting to the most restrictive environments and compatible with varying water qualities. Modular ALTAIR V5 can be fitted at any time an IZAR clip-on module converting it into a communicating meter, ready for mobile or fixed network (radio/wired) reading.

Features

  • DN15 / DN20
  • Q3 = 1.6 l/h (DN15) / Q3 = 2.5 l/h (DN15 and DN20) / Q3 = 4 l/h (DN20)
  • MID approval up to R=1000
  • Starting flowrate at 0.2 l/h (DN15) / 0.4 l/h (DN20)
  • Brass version (DN15 and DN20) and Composite version (DN20)
  • High dynamic range
  • Installation in any position
  • Metrological data
    Nominal diametermm1515151515152020202020202020
    Length*Lmm110110115145165170110165190110130165175190
    Nominal flow rateQ3m3/h1.62.52.52.52.52.52.52.52.544444
    R standard*Q3/Q1160160160160160160160160160160160160160160
    Starting flow ratel/h0.20.20.20.20.20.20.40.40.40.40.40.40.40.4
    Minimum flow rate*Q1l/h1015.6215.6215.6215.6215.6215.6215.6215.622525252525
    Transition flow rate*Q2l/h1625252525252525254040404040
    Maximum flow rateQ4m3/h23.133.133.133.133.133.133.133.1355555
    Head loss at Q3bar0.250.570.570.570.570.570.220.220.220.580.580.58/0.62**0.580.58/0.62**
    Head loss at Q4bar0.380.860.860.860.860.860.350.350.350.880.880.88/0.98**0.880.88/0.98**
    kvs (deltaP=Q²/Kvs²)3.243.343.343.343.343.345.335.335.335.255.255.25/5.06**5.255.25/5.06**
    * Other values on request
    ** Composite version
  • Approval
    ApprovalsMID: LNE - 39018 / Type A3 | UKCA
    StandardsISO 4064 | EN 14154 | OIML R49
    Sanitary conformityACS | AoC DEU | Belgaqua | DM 174 | OTH (DN20) | PZH | WRAS (DN20)
  • REACH

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)

  • Temperatures and pressure
    Water temperature°C0.1 ... +50
    Ambient operating temperature°C+1 ... +55
    Storage temperature°C-10 ... +55
    Nominal pressurePNbar16
  • Dimensions
    Nominal diametermm1515151515152020202020202020
    Length*Lmm110110115145165170110165190110130165175190
    Nominal flow rateQ3m3/h1.62.52.52.52.52.52.52.52.544444
    Housingbrassbrassbrassbrassbrassbrassbrassbrass/compositebrass/compositebrassbrassbrass/compositebrassbrass/composite
    WidthBmm83.583.583.583.583.583.591.391.3/9591.3/9591.391.391.3/9591.391.3/95
    HeightHmm110.1110.1110.4110.1110.1110.1124.4124.4/127.7124.4/127.7124.4124.4124.4/127.7124.4124.4/127.7
    HeightH1mm14.814.815.114.814.814.818.518.5/19.118.5/19.118.518.518.5/19.118.518.5/19.1
    HeightH2mm95.395.395.395.395.395.3105.5105.9/108.6105.9/108.6105.9105.9105.9/108.6105.9105.9/108.6
    Thread connectionsinch3/4"3/4"3/4" - 7/8"3/4"3/4"3/4"1"1"1"1"1"1"1" 1/41"
    Weightkg0.620.620.630.660.680.690.910.96/0.461.04/0.470.910.930.96/0.461.051.04/0.47
    * Other values on request
  • Precision curve

    This technology does not require straight length.

  • Options

    Non-return valve | Pair of connectors | Glass/metal register